Two 0.130 in. Diameter mtg holes spaced 1.125 in. C to c
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.380 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.800 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, single throw, normally closed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
250.0 ac and 32.0 dc
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
2.0 ac or 1.0 dc
MRC:
The amount of voltage for which the heater is designed,expressed in volts.CYCU
Heater Voltage Rating In Volts:
6.3
MRC:
The rated power that the heater can safely consume,measured in watts.CYCV
Heater Power Rating In Watts:
4.5
MRC:
A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
Delay Time In Seconds:
10.0 fixed operate
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-r-19648 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 wire lead
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-r-19648/1 government specification