رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Immersion proof; jcens, dynamotor-power supply, type no. Dy-105/grc-9x; jcens, radio set, type no. An/grc-9x
TXT
وصف:
Dynamotor-power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
14.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc and dc and dc and dc and dc and dc
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
580.0 volts
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no. An/grc-9x
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 3/8 in. Diameter mtg holes spaced on 7-1/4 in. By 12-3/8 in. C to c
MRC:
Indicates the type of rectifier provided.APTB
Rectifier Type:
Synchronous self-rectifying vibrator
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
100.0 milliamperes
MRC:
The input voltage rating at which the item is designed to operate.AXNK
Err Default:
Err default
MRC:
The input voltage rating at which the item is designed to operate.AXNK
Input Voltage Rating:
29.0 volts
MRC:
The amount of current for which the item is designed.AXNP
Current Rating:
25.0 milliamperes and 45.0 milliamperes and 575.0 milliamperes and 2.0 amperes and 500.0 milliamperes and 500.0 milliamperes
MRC:
An indication of whether or not a regulated output current is provided.AZMQ
Regulated Output Current:
Not provided
MRC:
An indication of whether or not an auxiliary alternating current output is provided.AZMR
Err Default:
Err default
MRC:
An indication of whether or not an auxiliary alternating current output is provided.AZMR
Auxiliary Ac Output:
Not provided
MRC:
An indication of whether or not a regulated current is provided.AZSK
Regulated Current:
Not provided and not provided and not provided and provided and provided and provided
MRC:
The amount of input current for which the item is rated.AZSL
Input Current Rating:
7.5 amperes
MRC:
An indication of whether or not a radio frequency filter is provided.AZSM
Err Default:
Err default
MRC:
An indication of whether or not a radio frequency filter is provided.AZSM
Radio Frequency Filter:
Provided