رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Tubing wall construction can also be laminated
TXT
وصف:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
70.0 single bend e-plane
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
1.118 inches all flanges and 1.126 inches all flanges
Flange Inside Height:
0.493 inches all flanges and 0.501 inches all flanges
Flange Outside Width:
1.860 inches all flanges and 1.890 inches all flanges
Flange Outside Height:
1.860 inches all flanges and 1.890 inches all flanges
Flange Inside Diameter:
1.253 inches all flanges and 1.360 inches all flanges
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.610 inches all flanges and 0.640 inches all flanges
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.166 inches all flanges single connection facility and 0.172 inches all flanges single connection facility
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
2.00
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.05
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
10.0 pounds per square inch gage
Waveguide Outside Width:
Between 1.246 inches and 1.254 inches
Waveguide Inside Width:
Between 1.118 inches and 1.126 inches
Waveguide Inside Height:
Between 0.493 inches and 0.501 inches
Waveguide Outside Height:
Between 0.621 inches and 0.629 inches
Waveguide Longer Offset Distance:
3.507 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole all flanges single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type all flanges
Waveguide Offset Distance:
Between 3.328 inches and 3.358 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy all flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy single tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film all tubing segment and flange outside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Bend type