رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.500 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
1 single indicator 1st range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
3 single indicator 6th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
5 single indicator 2nd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
5 single indicator 4th range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
6 single indicator 3rd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
6 single indicator 5th range
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Instruction book 1, test leads 2
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 kilovolts, af single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 amperes, dc single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 megohms single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-12.0/+55.0 decibels single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+5.0 kilovolts, ac single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+5.0 kilovolts, dc single indicator 5th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Portable
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 3 pct dc and 5 pct ac range single indicator single range
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
1.5 dc
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular or square
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by measurement ranges