رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
100000 operations min life
TXT
وصف:
Fault Locating Indicator
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
Between 0.345 inches and 0.355 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
1.010 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
12.0 volts
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
2
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Solder lug
MRC:
Indicates the type of presentation.AMNL
Presentation Type:
Window
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
2
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 threaded case
MRC:
The opposition that the coil offers to the flow of direct current.BDFT
Coil Dc Resistance:
220.0 ohms
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Mounting hardware
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Aluminum
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Shock, vibration, humidity, dc and insulation res, dielectric withstanding v per mil-std-202
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
650 mw min pulse power; 25 msec min operating pulse lg