رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Each unit produced shall be burn-ed in for 72 hours until the last 24 hours are failure free
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof and fungus proof and salt spray resistant
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/alq-117
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
55000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
115.0 ac pounds per hour wet single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
13.5 dc volts 1st power output and 16.5 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
4.0 dc volts 3rd power output and 6.0 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-14.0 dc volts 5th power output and -15.0 dc volts 5th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
-4.0 dc volts 4th power output and -6.0 dc volts 4th power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
400.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Over voltage protector and input to case isolation and input to output isolation and output to case isolation
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
10.0 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-0.4 dc amperes 4th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
-4.4 dc amperes 5th power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
4.0 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
5.5 dc amperes 1st power output
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
54.0