رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Reactor-transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
20 single component 1st secondary4 single component 2nd secondary100 single component single primary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
200.00 microhenries single component 1st secondary1.73 millihenries single component single primary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
15.0 kilohertz single component and 25.0 kilohertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.810 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.950 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
105.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single primary and winding turns single component single primaryelectrical single component all secondary and winding turns single component all secondary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 2 secondary single component
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.00795 inches american wire gage single component single primary0.02010 inches american wire gage single component all secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
0.1 amperes ac single component single primary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.025 single component 1st secondary0.010 single component 2nd secondary1.500 single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
2.00 ac pounds per hour with retaining chain single component 1st secondary10.90 ac pounds per hour dry single component single primary and 19.50 ac pounds per hour with retaining chain single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
7 wire lead