رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Foot-mounted with relief valve
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Foot
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded internal
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Close coupled
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Astute class submarine
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
1.14 liters per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
150.0 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
100.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Clockwise and counterclockwise
MRC:
The design of a rotary pump as determined by the mechanical principle used to achieve movement of the fluid.AHZR
Rotary Pump Design:
Gear
MRC:
The means by which the item is operated.AHZT
Operation Method:
Powered
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Machine keyway
MRC:
The length of a straight line which passes through the center of the drive shaft end,and terminates at the circumference.AJAC
Drive Shaft End Diameter:
0.50 inches
MRC:
A measurement of the distance the drive shaft extends from the housing.AJAD
Drive Shaft Length:
1.34 inches
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
0.75-14 npt
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
0.75-14 npt
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Integral relief valve