رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
2 inch controlvalve
TXT
وصف:
Flow Control Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
O-ring, dilating
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
1
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
Designates the size of the valve.CCFG
Valve Size:
2.000 inches
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
300.0 pounds per square inch water
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Copper alloy
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
300.0 degrees fahrenheit water
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
110.0 ac and 24.0 dc
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 mounting bracket