رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Quick Disconne Coupling Assembly
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3a first fluid end connection
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.540 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator (non-core):
Err-090
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACMR
Second End Thread Class:
3b
MRC:
A measurement of the longest dimension of the second leg, in distinction from width.ADLL
Second Leg Length:
0.781 inches
MRC:
The means by which mechanical action completely engages or disengages a mating quick disconnect part.ADLN
Quick Disconnect Method:
Spring push-pull all ends
MRC:
A narrative description of the type of end connection.ADMB
Second Fluid End Connection Type:
Threaded internal boss
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
135.0 degrees celsius single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Flareless first fluid end connection
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
0.625 inches
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external tube first fluid end connection
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-sealing
MRC:
Indicates whether or not the second end is identical to the first end.CQBB
Second End Relationship With First End:
Not identical
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
3000.0 pounds per square inch any acceptable
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.875 inches first fluid end connection
MRC:
The angle of the end surface upon which the mated surface seats.CQRB
Seat Angle:
12.0 degrees
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CRNB
Second End Thread Size:
0.875 inches
MRC:
A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CRPF
Second End Thread Series Designator:
Unf
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
135.0 degrees celsius any acceptable
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.625 inches first fluid end connection
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Anodize
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Coupling assembly
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator: