رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Signal Generator
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Rack
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.718 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 63.0 hertz
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Enamel
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+6.000 to 18.000 megahertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/flr-9
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Signal generator
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Sg1002/flr9/v)
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current load.AMNE
Output Impedance Rating:
75.0 ohms
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
1 part per million
MRC:
The number of fixed frequencies provided.BHFX
Fixed Frequency Quantity:
6
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Provided
MRC:
An indication of the calibrated signal range that is output by the item.BHFZ
Calibrated Signal Output Range:
Plus 20 dbm porm 1 db
MRC:
An indication of the signal output constancy.BHGC
Signal Output Constancy:
Better than one part in one hundred million per second over 30 second averaging period
MRC:
The number of alternating current phases.FAAZ
Phase:
Single