رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
3431-1130-4067
معلومات الجزء
W/cold weather starting device 1
TXT
وصف:
Arc Welding Machine
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Wheel
MRC:
The number of wheels included on the item.AGDH
Wheel Quantity:
4
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Set welding cables 1, cable storage cabinet 1, hour meter 1, overspeed protection device 1
MRC:
Indicates the type of tire(s) provided.ALRE
Tire Type:
Pneumatic
MRC:
The speed at which an item has been tested and rated to perform without damage or failure of the rotating components,expressed in revolutions per minute.AMZE
Rotational Speed Rating In Rpm:
Any acceptable
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
Any acceptable
MRC:
The rated power output for which the item is designed.ANLH
Power Output Rating:
Any acceptable
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Dc
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
115.0
MRC:
The current the item will permit to pass,expressed in amperes.ANYP
Output Current Rating In Amps:
Between 350.0 and 400.0
MRC:
Indicates the design type of the item.APGF
Design Type:
Generator
MRC:
The source of power which drives the item.ATJK
Power Source:
Diesel engine
MRC:
The name of the manufacturer of the engine furnished.ATJL
Engine Manufacturer Name:
A/a
MRC:
The number used by the manufacturer for identifying the engine.AYHQ
Engine Manufacturer Identifying Number:
A/a
MRC:
Indicates the type of current of the arc.CDRR
Arc Current Type:
Dc
MRC:
The minimum current which must be maintained at a specified voltage.CDRS
Minimum Current At Specificationified Voltage:
80 amp at 23v
MRC:
The maximum current which must not be exceeded at a specified voltage.CDRT
Maximum Current At Specificationified Voltage:
500 amp at 40v
MRC:
Indicates the type of operator for which the item is designed.CDRW
Operator Type For Which Designed:
Single
MRC:
An indication of whether or not a remote control design is included.CDRY
Remote Control Design:
Not included
MRC:
An indication of whether or not an auxiliary power output design is included.CDRZ
Auxiliary Power Output Design:
Included
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
3 type and 400 size