رقم الجزء 3433-425

Spectrum Analyzer

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
3433-425
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
008571105
NSN
رقم المخزون الوطني:
6625-00-857-1105 6625008571105
TXT
وصف:
Spectrum Analyzer
INC
INC
رمز اسم العنصر:
00833
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
11.000 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.500/+25.000 kilohertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Power cable 1 and 5 spare fuses
MRC:
The total opposition (resistive and reactive) presented by the item to an alternating current source.AMND
Input Impedance Rating:
15.0 kilohms
MRC:
The number of specified ranges of frequencies or wavelengths operating between two stated limits.ANLC
Frequency Band Quantity:
1
MRC:
Indicates the type of unit.APQB
Unit Type:
Standard
MRC:
The limits of permissible variance from the standard/true value,expressed in percent.AREL
Frequency Calibration Accuracy Range In Percent:
-3.0/+3.0
MRC:
An indication of the minimum to maximum scale of the meter.BHZH
Meter Scale Range:
Center indication only
MRC:
The acceptable limits of deviation from the designed standard output value of the meter,expressed in percent.BHZJ
Meter Accuracy Range In Percent:
-2.0/+2.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Analyzer, spectrum

{lang[cimilar]} Spectrum Analyzers

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
قارن الآن»