رقم الجزء 347224-B21

Uninterruptible Power Supply

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
347224-b21
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
015240406

معلومات الجزء
R6000 extended runtime module

NSN
رقم المخزون الوطني:
6130-01-524-0406 6130015240406
TXT
وصف:
Uninterruptible Power Supply
INC
INC
رمز اسم العنصر:
67374
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
24.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
17.250 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
The ratio of permissible frequency deviation from the controlled constant value,expressed in percent.ANRQ
Frequency Regulation Percent:
0.5 multiple power outputs w/identical ratings
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
200.0 ac pounds per hour wet 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
208.0 ac pounds per hour wet 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
220.0 ac pounds per hour wet 3rd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac pounds per hour wet 4th alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 ac pounds per hour wet 5th alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
200.0 ac volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
208.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
230.0 ac volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st alternate operating power rqmt and 60.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 2nd alternate operating power rqmt and 60.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 4th alternate operating power rqmt and 60.0 hertz 4th alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 5th alternate operating power rqmt and 60.0 hertz 5th alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 3rd alternate operating power rqmt and 60.0 hertz 3rd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
50.0 hertz multiple power outputs w/identical ratings and 60.0 hertz multiple power outputs w/identical ratings
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+50.0/+104.0 degrees fahrenheit
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
6000.0 watts multiple power outputs w/identical ratings
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
26.0 ac amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
29.0 ac amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
30.0 ac amperes 3rd power output
MRC:
An indication of whether or not the battery is rechargeable and the type of battery.CWHY
Battery Feature And Type:
Rechargeable lead acid cell
MRC:
The time required to charge a battery(ies) to its rated capacity after a period of discharge.CWWB
Battery Recovery Time:
120.0
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
15.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
length including bezel 25.750 inches; input voltage user selectable; electrical input connection is hardwired; electrical output connections (3) iec-320 16 amp and (12) iec-320 10 amp divided into 5 load segments; output protection one 10 amp resettable circuit breaker for each load segment; 2 serial communication ports for intelligent power management software and option cards; user light emitting diode (led) green-normal operation yellow-on battery yellow-on bypass red-alarm; two-line lcd. With 3 button control; storage temperature 32.0 to 77.0 degrees f; operating humidi type 20.0 to 80.0 percent non-condensing

{lang[cimilar]} Uninterruptible Power Supplies

« Converters Electrical Nonrotating {lang[catalog]}
قارن الآن»
واضح | أخفى