رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Microcircuit, linear dual precision op amp
TXT
وصف:
Linear Microcircuit
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.355 inches and 0.400 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.240 inches and 0.260 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.180 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Nha 114e9274g2 cage 89954 e/i c-17a aircraft
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrostatic sensitive and selected item
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Plastic
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Dual-in-line
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
2 amplifier, operational, general purpose
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
-22.0 volts power source and 22.0 volts power source
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Extended temperature range testing at -55 to + 125 degrees celsius of pns lt1013dip cage 01295 and lt1013in8 cage 64155
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
89954-356a1301 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) and 89954-356a1407 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 printed circuit