رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Audio
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.781 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
"t"
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.500 inches
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0/+4.4
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Stepped
MRC:
The number of intervals at which the item can be set.ASYG
Step Position Quantity:
22
MRC:
The amount of attenuation between adjacent steps,expressed in decibels.ASYH
Attenuation Per Step In Decibels:
0.2
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-0.22/+0.22
MRC:
The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
Mounting Thread Quantity:
32 per inch
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
Mounting Facility Screw Thread Diameter:
0.164 inches
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
1000.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug