رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
2 coils, 48 vdc contacts rated at 15 ma
TXT
وصف:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
6
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Threaded stud
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
2gvortac, rta-2 antenna, fa-6237 control panel
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 4-40 thd mtg studs spaced 2-1/4 in. C to c
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
48.0 volts
MRC:
The number and combination/s/ of the basic contact forms,in the order of assemblage,which make up the switching structure of the main contact/s/.APDY
Main Contact Form Arrangement:
2a1b
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
1.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
48.000
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+330.0/+1000.0 microamperes
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Decrease value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Permanent magnet
MRC:
The means by which the item is released.APNT
Release Method:
Electromagnetic
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
2.484 inches
MRC:
The length of a straight line which passes through the center of the mounting flange,and terminates at the circumference.APTE
Mounting Flange Diameter:
3.020 inches
MRC:
A measurement of the longest dimension of the meter body,in distinction from width.APTG
Err Default:
Err default
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Meter, relay, (tacan speed-control meter)
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Mk 13056, instruction book, rtn equipment antenna group, model rta-2, sec 1-12, fa-6237 control panel, pg 10-56; m 13056, fa-6237a control panel, pg 10-13