رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The designation describing the method used in forming the core.ACZR
Core Construction:
S0lid single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.500 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.250 inches
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.250 single component single winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
110.00 ac pounds per hour wet single component single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead w/lug