رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
3ct180
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
006482348

معلومات الجزء
Primary rated but not included

NSN
رقم المخزون الوطني:
5950-00-648-2348 5950006482348
TXT
وصف:
Current Transformer
INC
INC
رمز اسم العنصر:
00738
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
25.0 hertz single component and 133.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The maximum amount of power for which the transformer is rated.ACZF
Maximum Transformer Power Rating:
2.0 volt-ampere single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.062 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
3.250 inches
MRC:
The type of installation for which the item is designed.AFHN
Installation For Which Designed:
Indoor nonportable
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
5.0 amperes dc single component single secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
80.0 amperes dc single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead