رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
40161-6655-56kc
TXT
وصف:
Quartz Crystal Unit
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 0.757 inches and 0.800 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 0.192 inches and 0.217 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.750 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.565 inches and 0.583 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.720 inches
MRC:
A measurement of the smallest dimension of a body,in distinction from length or width.ADPR
Body Thickness:
0.315 inches
MRC:
An overall measurement of the smallest dimension of an item,in distinction from length or width.ADUM
Overall Thickness:
0.345 inches
MRC:
The length of a straight line which passes through the center of a terminal,and terminates at the circumference.AEBT
Terminal Diameter:
Between 0.048 inches and 0.052 inches
MRC:
The mode of frequency at which the device is designed to operate.AEHC
Mode Of Oscillation:
Fundamental
MRC:
The frequency at which the item is designed to operate under specified conditions.AEHG
Specified Frequency:
6.65556 megahertz
MRC:
The permissible frequency deviation when operating at the reference temperature,expressed in percent.AEHK
Frequency Tolerance At Reference Tempurature In Percent:
-0.004/+0.004
MRC:
The temperature at the midpoint of the controlled operating temperature range.AEHM
Controlled Reference Temp:
75.0 degrees celsius
MRC:
The temperature range over which units,designed for controlled temperature conditions,will oscillate.AEHN
Operable Tempurature Range:
-50.0/+85.0 degrees celsius
Center To Center Distance Between Terminals:
0.476 mils and 0.496 centimeters
MRC:
The permissible frequency deviation within the operating temperature range,expressed in percent.CRFX
Frequency Tolerance For Operating Tempurature In Percent:
-0.007/+0.007
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Oval body, pin terminals
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-milc16836 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).