معلومات الجزء
Digital test and switching controller
TXT
وصف:
Electronic Syste Test Controller
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+65.0/+78.0 degrees fahrenheit
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
115.0 ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
AN/G-SM-358-NSN4
MRC:
The source of power which drives the item.ATJK
Power Source:
External
MRC:
A maximum measurement of the longest dimension of an item,in distinction from width.CHQP
Maximumlength:
22.160 inches
MRC:
The maximum measurement taken at right angles to the length of an item,in distinction from thickness.CHQQ
Maximumwidth:
10.470 inches
MRC:
The maximum distance measured in a straight line from the bottom to the top of an item.CHQR
Maximumheight:
19.000 inches
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Rcontains 2 separate test module adapters-one for the ica switching modules and the other for the dtm; the controller also provides the fixed voltage (+5v and +13v) power supplies required for the ica switching modules
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
57.0 and 63.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used with the 4010669 interface connector assemblies and digital test module system