رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.130 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.500 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Dry
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Air
MRC:
The basic design of the muffler.ARND
Muffler Design:
Baffle
MRC:
The number of baffles included on the item.ARNE
Baffle Quantity:
1
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Universal
MRC:
The location of the inlet.ARNJ
Inlet Location:
Located on side opposite outlet and offset 0.594 in. To right of vertical center line looking from outlet end
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
1.180 inches
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
2.000 inches
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
1.180 inches 1st outlet
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
2.000 inches single inlet
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Rectangle
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
2 holes
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
0.179 inches
MRC:
The spacing of the inlet flange mounting provision.ARNT
Inlet Flange Mounting Provision Spacing:
3.469 in. C to c dim. Of holes
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
101 round hole err-100
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
101 round hole
MRC:
Indicates the location/s/ of the nonconnection outlet on the item.ARXZ
Nonconnection Outlet Location:
Located symetrically offset on alternate center lines vertically and horizontally
MRC:
Designates the size of the nonconnection outlet included on the item.ARYA
Nonconnection Outlet Size:
Holes 0.139 in. Min, 0.144 in. Max
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Aluminum