رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
420eq-10l-1807
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b single pressure connection
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.625 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
3.000 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.312 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.281 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
3.000 inches
MRC:
The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
Pressure Switch Type:
Differential
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 35.0 degrees fahrenheit and 120.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
18 single pressure connection
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.562 inches single pressure connection
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Wire lead
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
3.5 amperes inductive load single voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point not adjustable and actuation point adjustable, preset
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+0.00/+30.00 actuation point dynes per square centimeter
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External actuation point screw
MRC:
The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
Contact Stimulus Rating:
13.70 actuation point pounds per square inch gage and 14.30 actuation point pounds per square inch gage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
440.0 ac at sea level single voltage
MRC:
Indicates the type of pressure connector.CTZL
Pressure Connector Type:
Swivel nut, compression, threaded internal single connection
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Cylindrical w/mounting lugs
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf single pressure connection