رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Manufacturers suggested name is valve assembly, stablizer flow control; pressures: operating 3000 psig, proof 4500 psig, burst 7500 psig; ports per ms33649-8; ambient temps -65 to +160 degrees feh; coil resistance 47 ohms min; filter element rating 25 micron absolete; dimensions: length 7.7 inches, width 5.2 inches, height 4.8 inches; dry wt 5.5 lbs
TXT
وصف:
Directional Control Linear Valve
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3b
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
7.6 gallons per minute
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Applicable t.O. 9h8-4-168-3 fig 13; u/o code c
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic and solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal boss
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Base mounted
MRC:
The maximum pressure at which an item is rated to operate for each type of service with which an item may be used.CQCJ
Maximum Operating Pressure And Media For Which Designed:
3000.0 pounds per square inch hydraulic fluid, petroleum base
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat and agav
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
160.0 degrees fahrenheit hydraulic fluid, petroleum base
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
18.0 dc and 30.0 dc
MRC:
The number of spools provided.CYHB
Spool Quantity:
4
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unjf
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 lever
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentitaed by source control drawing