رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
16
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Temp, in degrees celsius
MRC:
A measurement of the longest dimension of a mounting flange, in distinction from width.ADMG
Mounting Flange Length:
4.710 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
4.270 inches
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.161 in. Diameter mtg holes on 4.000 in. By 3.560 in. Mtg centers
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
28.0 volts
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The rated power that the main contact/s/ can safely consume or provide.APED
Err Default:
Err default
MRC:
The rated power that the main contact/s/ can safely consume or provide.APED
Main Contact Wattage Rating:
7.0 watts
MRC:
Indicates the type of current used by the auxiliary contact/s/.APEH
Err Default:
Err default
MRC:
Indicates the type of current used by the auxiliary contact/s/.APEH
Auxiliary Contact Current Type:
Dc
MRC:
The current rating of the auxiliary contact(s).APEL
Err Default:
Err default
MRC:
The current rating of the auxiliary contact(s).APEL
Auxiliary Contact Current Rating:
5.0 amperes
MRC:
The amount of voltage for which the auxiliary contact(s) is rated.APGM
Err Default:
Err default
MRC:
The amount of voltage for which the auxiliary contact(s) is rated.APGM
Auxiliary Contact Voltage Rating:
25.0 volts
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
7.000
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Flush
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Decrease value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Not provided
MRC:
The rated power that the auxiliary contact/s/ can safely consume or provide.APRB
Err Default:
Err default
MRC:
The rated power that the auxiliary contact/s/ can safely consume or provide.APRB
Auxiliary Contact Wattage Rating:
7.0 watts
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.790 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
5.500 inches