رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Engine Generator Regulator
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Threaded stud
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.266 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the mounting.ADER
Mounting Style:
Three hole triangular
Distance Between Holes Along Width:
2.500 inches
MRC:
An indication of whether or not the item is provided with a self-contained shock mount.AGBC
Shock Mount:
Not provided
MRC:
An indication of whether or not shielding against radio interference is provided.ALBH
Radio Interference Shielding:
Not provided
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
Between 28.4 and 28.6
MRC:
The electrical voltage of the system for which the item is designed.ANYC
System Voltage Rating:
24.0
MRC:
Indicates the type of ground the electrical system utilizes.ANYD
System Ground Polarity:
Negative or positive
MRC:
Indicates the type of device used to maintain a constant voltage.ANYE
Voltage Regulator Unit Type:
Wire wound coil
MRC:
The number of individual voltage regulator units contained in the item.ANYH
Voltage Regulator Unit Quantity:
1
MRC:
Indicates the type of device used to limit the current output to the maximum safe value.ANYJ
Current Regulator Unit Type:
Wire wound coil
MRC:
The number of individual current regulator units contained in the item.ANYK
Current Regulator Unit Quantity:
1
MRC:
The current the item will permit to pass,expressed in amperes.ANYP
Output Current Rating In Amps:
Between 15.5 and 16.0
MRC:
Indicates the type of device used to close and open (break) the circuit.ANYR
Circuit Control Device Type:
Cutout relay
MRC:
The cut-in voltage/s/ required to close the circuit.ANYS
Cut-in Voltage Rating:
Between 22.0 and 22.5
MRC:
An indication of whether or not a reverse current overload circuit breaker is included.ANZB
Reverse Current Overload Circuit Breaker:
Not included
MRC:
An indication of whether or not a field relay unit is included.ANZC
Field Relay Unit:
Not included
MRC:
An indication of whether or not the terminal(s) is encased.ANZE
Terminal Encasement:
Not encased
Center To Center Distance Between Holes Along Width And Hole Along Length:
7.125 inches