رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up nonsymmetrical
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket single mounting facility and threaded hole single mounting facility
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32 single mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
250.0 highest dc voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
28.0 lowest dc voltage rating at sea level
MRC:
The position of the actuator,with relation to the extremity of rotation,that is momentary (spring loaded).CQQT
Switch Actuator Momentary Position:
Counterclockwise single actuator
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position circular single mounting facility
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
2 single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab w/screw
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
90.0 degrees single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
15.0 amperes resistive load lowest dc voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
5.0 amperes resistive load highest dc voltage rating at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Tap, circuit selector
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single mounting facility