رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
A measurement of the pipe size the item will accommodate.AAAR
Pipe Size Accommodated:
2.000 inches 1st end
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
28.9 degrees celsius 2nd response
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
399.0 degrees celsius 1st response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Beveled (pipe) 1st end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.312 inches 1st end and 1.438 inches 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Butt weld pipe 1st end
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
1435.0 pounds per square inch 2nd response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
1660.0 pounds per square inch 1st response
MRC:
The angle that the flow is turned from the straight flow.CRFY
Flow Angle:
45.0 degrees
MRC:
The term used to define the wall thickness cross-sectional dimension of pipe of various material as presented by a schedule,thickness class,class strength,or weight designation.CWFG
Pipe Wall Thickness Designation For Which Designed:
Schedule 80 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm a234, gr b assn standard single material response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Steam 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water-oil-gas 2nd response