رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
462a023-2586-0
معلومات الجزء
Transition, one to three cables
TXT
وصف:
S Electrical Insulation Sleeving
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-55.0 degrees celsius and 120.0 degrees celsius
MRC:
The element,compound,or mixture with which the item is coated,excluding any surface treatment.ADYY
Coating Material:
Raychem precoat no. 25, high-performance adhesive no. S-1048
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fluid resistant
Main Body Inside Diameter:
0.520 inches after unrestricted recovery
Main Body Inside Diameter:
1.000 inches as supplied
First Branch Inside Diameter:
0.270 inches after unrestricted recovery
First Branch Inside Diameter:
0.460 inches as supplied
Second Branch Inside Diameter:
0.270 inches after unrestricted recovery
Second Branch Inside Diameter:
0.460 inches as supplied
Third Branch Inside Diameter:
0.270 inches after unrestricted recovery
Third Branch Inside Diameter:
0.460 inches as supplied
Distance From Intersecting Centerline Of Main Body To End Of First Branch:
1.980 inches after unrestricted recovery
Main Body Wall Thickness:
0.100 inches after unrestricted recovery
First Branch Wall Thickness:
0.060 inches after unrestricted recovery
Second Branch Wall Thickness:
0.060 inches after unrestricted recovery
Third Branch Wall Thickness:
0.060 inches after unrestricted recovery
Distance From Edge Of Main Body To Intersecting Centerlines:
1.690 inches after unrestricted recovery
Main Bodylength:
3.670 inches after unrestricted recovery
Angle Between Main Body And First Branch Centerlines In Deg:
30.0 after unrestricted recovery
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Propulsion section assembly, rmv; an/wld- (v) mine hunting sys
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Fluid resistant modified elastomer
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Fluid resistant modified elastomer
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-1 to 3 cables