رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Ansi type jx multipair extension cable
TXT
وصف:
Electrical Special Purpose Cable
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
105.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.390 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
8
MRC:
Indicates the type and number of accessory wires furnished with the item.AWTB
Accessory Wire Type And Quantity:
1 drain and 1 ground
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Solid all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
20 awg all conductors
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 1st position primary insulation first conductorred 1st position primary insulation second conductorwhite 1st position primary insulation third conductorred 1st position primary insulation fourth conductorwhite 1st position primary insulation fifth conductorred 1st position primary insulation sixth conductorwhite 1st position primary insulation seventh conductorred 1st position primary insulation eighth conductorblack 4th position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Iron core conductor first conductorconstantan core conductor second conductoriron core conductor third conductorconstantan core conductor fourth conductoriron core conductor fifth conductorconstantan core conductor sixth conductoriron core conductor seventh conductorconstantan core conductor eighth conductorplastic polyvinyl chloride 1st position primary insulation all conductorsplastic polyethylene terephthalate 2nd position tape cablealuminum 3rd position shield foil cable and plastic polyethylene terephthalate 3rd position shield foil cableplastic polyvinyl chloride 4th position jacket cable
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
4jx20pp, cagec 29907 mfr ref all material responses core conductor all conductors