رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
4phs311-060404
معلومات الجزء
Cryofit end connections
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
-65.0 degrees fahrenheit 1st response
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
275.0 degrees fahrenheit 2nd response
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Aircraft; b-2 bomber
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain (tube) all ends
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.133 inches 1st end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
0.939 inches 2nd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
0.939 inches 3rd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded external tube all ends
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
4000.0 pounds per square inch single response
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.250 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.250 inches 3rd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.375 inches 1st end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.044 inches 2nd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.044 inches 3rd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.057 inches 1st end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Titanium alloy
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Ams4965 assn standard single material response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Aeronautical fluid single response