رقم الجزء 5113

Oscilloscope

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
5113
تجريد:
Yes - DEMIL/MLI
صلاحيه:
وحدة القياس:
NIIN:
010870513
NSN
رقم المخزون الوطني:
6625-01-087-0513 6625010870513
TXT
وصف:
Oscilloscope
INC
INC
رمز اسم العنصر:
00357
INC
COM
امتثال:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
20.400 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
11.900 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.400 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 440.0 hertz
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
110.0 volts and 220.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
2
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Internal 8 x 10 div, 1.27 cm/div
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
6.5 in. Square
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
0.1 microseconds
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Provided
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Provided
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Included
MRC:
The number of writing gun(s) included with the item.BHFL
Err Default:
Err default
MRC:
The accelerating voltage for which the writing gun is rated.BHFM
Err Default:
Err default
MRC:
An indication of whether or not trace erasing provisions are provided.BHFR
Trace Erasing Provision:
Provided
MRC:
An indication of the function of the plug in units and the number provided.BHFS
Plug In Unit Function And Quantity:
Vertical deflection 2, horizontal deflection 1

{lang[cimilar]} Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
قارن الآن»
واضح | أخفى