رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Control Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
13.250 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
22.500 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Includes voltmeter to monitor input power and internally generated voltages; internal power supply to generatate necessary b plus voltages, variousspecial test points; lights, jacks, and switches to indicate power operationof certain circuits; steel and aluminum box w/ cover
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Multiple item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Tests control box
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
13.250 inches
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Input impedance 100 kilohms max; output impedance 25 kilohms max; output level 0.0 to 6.0 dbm