رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Nickel plated brass. Mounting hole 0.480.
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Bushing mount
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
1.169 inches
MRC:
A measurement of the longest dimension of a bushing,in distinction from width.ABXD
Bushing Length:
0.413 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.846 inches
MRC:
The number of actuators provided in the item for selection of switching positions.AFCG
Switch Actuator Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the actuator.AFUQ
Actuator Style:
Round
Actuator Height:
0.689 inches
MRC:
The relationship between the actuator position and the actuator action /maintained or momentary/.AFUX
Actuator Position-action Relationship:
Up position momentary and center position maintained and down position maintained
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
250.0 ac and 24.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Boiler combustion monitoring system lha/lhd
Mounting Surface To Terminal End Distance:
1.279 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.469 inches
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
15.000 amperes resistive ac and 10.000 amperes resistive dc
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Uns
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug