رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electronic Control Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 22.147 inches and 22.187 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 8.170 inches and 8.290 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
15.030 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Shock resistant and vibration
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+5.0/+25.0
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
115.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+60.0 degrees celsius
MRC:
The numeric value of the life expectancy of the item.AFHH
Average Life Rating:
10000.0
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Hours
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
10000.0
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
Not rated
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
30.0 hertz output channel
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
Not rated
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
Not rated
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
Not rated
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
Not rated
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
Not rated
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative operating channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Negative output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive operating channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive input channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
Not rated
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Output channel radio frequency
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
6 light
MRC:
The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
Shock Pulse Duration Time:
7.0 milliseconds
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
400.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
440.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Three