رقم الجزء 564286

Stepping Switch

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
564286
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
007866268
NSN
رقم المخزون الوطني:
5930-00-786-6268 5930007866268
TXT
وصف:
Stepping Switch
INC
INC
رمز اسم العنصر:
26954
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.797 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.660 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The means of attaching the item.ADJH
Mounting Method:
Base
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Direct
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four no. 8/0.164/-32 in. Tapped mtg holes on 1.968 in. By 3.661 in. Mtg centers
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
24.0 volts
MRC:
The means of restoring the item to a homing position.ANZW
Homing Method:
Through off-normal springs
MRC:
The number of bank levels provided.ANZX
Bank Level Quantity:
12
MRC:
The number of contact/s/ /point/ provided in each bank level.ANZY
Contact Quantity Per Bank Level:
15
MRC:
The number of wiper contacts provided in each bank level.ANZZ
Wiper Contact Quantity Per Bank Level:
12
MRC:
The amount of current for which the contact/s/ was designed.APAA
Contact Current Rating:
1.0 amperes
MRC:
Indicates the type of contact/s/ used.APAB
Contact Type:
Nonbridging
MRC:
The number of nonbridging levels provided.APAD
Nonbridging Level Quantity:
12
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
Indicates the type of coil used.APAG
Coil Type:
Drive
MRC:
The basic form of the auxiliary off-normal contact arrangement.APCD
Auxiliary Off-normal Contact Arrangement:
1c
MRC:
The basic form of the auxiliary interrupter contact arrangement.APCE
Auxiliary Interrupter Contact Arrangement:
1b
MRC:
An indication of the stepping direction.APCJ
Stepping Direction:
Unidirectional
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Telephone switch stepping

{lang[cimilar]} Stepping Switches

« Switches {lang[catalog]}
قارن الآن»
واضح | أخفى