رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Standoff Insulator
MRC:
The application of color or a series of colors for the expressed purpose of identifying the specific functional design and/or the system application of an item.AAPC
Identification Code Color:
White
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.750 inches
MRC:
The maximum potential gradient that the insulating material can withstand per mil /0.001 inch/ thickness without rupture.ACGY
Dielectric Material Voltage Rating Per Mil Thickness In Volts:
249.0
MRC:
The length of a straight line which passes through the center of the circular top, and terminates at the circumference.AJQL
Top Diameter:
0.375 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Electrical termination unc err-100 err-100
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Mounting facility unc err-100 err-100
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Electrical termination unc
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter,and the thread location.CQBP
Screw Thread Series Designator And Location:
Mounting facility unc
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal thread axis,and the location.CQJM
Thread Length And Location:
0.250 electrical termination inches err-100 err-100
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal thread axis,and the location.CQJM
Thread Length And Location:
0.250 mounting facility inches err-100 err-100
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal thread axis,and the location.CQJM
Thread Length And Location:
0.250 electrical termination inches
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal thread axis,and the location.CQJM
Thread Length And Location:
0.250 mounting facility inches
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
32 electrical termination err-100 err-100
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
32 mounting facility err-100 err-100
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
32 electrical termination
MRC:
The number of screw threads on the item per linear inch,including incomplete threads,on a line parallel to the thread axis and the thread location.CQTP
Screw Thready Qty Per Inch (tpi) And Location:
32 mounting facility
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.138 mounting facility inches err-100 err-100
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.138 electrical termination inches err-100 err-100
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.138 electrical termination inches
MRC:
The length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread and terminates at the circumference,and the thread location.CRFL
Screw Thread Diameter And Location:
0.138 mounting facility inches
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b electrical termination err-100 err-100
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b mounting facility err-100 err-100
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b mounting facility
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread and the location.CRPG
Thread Class And Location:
2b electrical termination
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.MTLC
Material And Location:
insulation, electrical, mil-i-10, grade l522
MRC:
The plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the item and its location.STLC
Surface Treatment And Location:
glazed
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Pillar
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
249.0 volts per military /0.001 inch/