رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Discharge: 0.50 in. Threaded mnpt; input: 0.375 threaded fnpt; power cord: 6 ft; shut off head: 21 or 15 ft
TXT
وصف:
Centrifugal Pump Unit
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Explosion proof
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The means of cooling used to maintain the required operating temperature of the item.AENK
Cooling Method:
Blower cooled
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
USED-W/-NSN-6740
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
625.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
6.5 pounds per square inch gage
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3100.0 revolutions per minute
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.4
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
180.0 watts
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0