رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
5962-8859301mpa
معلومات الجزء
Microcircuits, low-off, low power dual operational amplifier, monolithic silicon
TXT
وصف:
Linear Microcircuit
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
A/f-18-dcn e/i fscm 76301
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Low power and monolithic
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Dual-in-line
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 amplifier, power
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
20.0 volts input
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
D-4 (8 lead .405" x .310" x .200") dual in-line package
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 printed circuit