رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Direct Current Generator
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
16.938 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
24.688 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
13.938 inches
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Dripproof-15 deg
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Compound wound
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
Indicates the type of excitor provided.AYHE
Excitor Type:
Self-excited
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Natural convection ventilated
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Nema
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
9.500 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
50.0 operating degrees celsius and 40.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
2400.0 single full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
11.000 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
250.0 line to neutral single output