رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Permanent magnet field
TXT
وصف:
Tachometer Generator
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
6.031 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
3.750 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.3120 inches single end
Flatted Portion Length:
0.4060 inches single end
Flat Depth:
0.1250 inches single end
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
The speed at which the calibration is determined,expressed in revolutions per minute.BFLQ
Calibration Speed In Rpm:
1000.0
MRC:
An indication of the type of calibration voltage output,expressed in volts.BKPC
Calibration Voltage Output Type In Volts:
50.0 dc
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.250 inches single end
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
50.0 line to neutral single output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 plug