رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Safety Relief Valve
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
40.0 gallons per minute
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
3930-01-378-7497
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal tube all ends
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
12 1st end
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
12 2nd end
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches 3rd end
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.062 inches 1st end
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
1.062 inches 2nd end
MRC:
The predetermined pressure at which the item is calibrated to open.CSDC
Opening Pressure Setting:
2000.0 pounds per square inch
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un 1st end
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Un 2nd end
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf 3rd end