رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.219 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.500 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
8 single indicator single range
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
One instruction book, two alligator clips, two test leads
MRC:
The rated sensitivity of the item.ANTG
Sensitivity Rating:
120.0 milliamperes
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.0/+1.0 at full scale single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 kilohms single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 megohms single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+12.0 amperes, dc single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+12.0 milliamperes, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-20.0/+77.0 decibels single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+6.0 kilovolts, ac single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+6.0 kilovolts, dc single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+60.0 microamperes, dc single indicator 7th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Portable
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 1.5 dc and 30.0 dc
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square