رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Ventilation duct
MRC:
Indicates the heat medium type for which the unit is designed.ABAM
Heat Medium Type:
Air
MRC:
The number of heat outlets included on the item.ABAW
Heat Outlet Quantity:
1
MRC:
The direction in which the heat is discharged from the item.ABAX
Heat Delivery Direction:
Horizontal
MRC:
Indicates the type of outlet(s) provided for the discharge of heat.ABAY
Heat Discharge Outlet Type:
Stationary
MRC:
Indicates the device/s/ provided for the purpose of directing the flow of heat.ABAZ
Heat Directing Device:
Flexible ducts
MRC:
The mechanism used for air circulation.ABBA
Air Circulation Device:
Propeller fan
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Single speed
MRC:
The maximum rated capacity of air flow moved through the item.ABBD
Maximum Air Flow Rate:
20.0 cubic feet per minute
MRC:
Indicates the type of air the item is designed to circulate.ABBE
Circulated Air Type:
Heated
MRC:
Indicates the type of device(s) installed on or around the equipment which eliminates undesirable radio interference waves.ABFG
Radio Interference Suppression Type:
Any acceptable
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
Between 7.560 inches and 7.680 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
2.780 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of device which controls the operation of the item.ALYC
Operating Control Type:
Any acceptable
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.8
MRC:
Indicates the type of heating element provided.BDXJ
Heating Element Type:
Electric nonimmersion
MRC:
The rate of heat delivery of the item.CQXD
Heat Delivery Rate:
1200.0 british thermal unit
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
208.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
6.480 inches
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
96906-mil-std-454 standard (includes industry or association standards, individual manufactureer standards, etc.).