رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Optical Microscope
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
2.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
6.000 inches
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Not provided
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Tool making
MRC:
Indicates the design type of the item.APGF
Design Type:
Research model
MRC:
The power and/or amount of apparent enlargement by an optical device.BLPR
Magnification:
10.0x and 30.0x and 50.0x
MRC:
Indicates the type of nonstereoscopic unit provided.BMLT
Nonstereoscopic Type:
Monocular
MRC:
An indication of the position of the body tube.BMLW
Body Tube Position:
Vertical
MRC:
An indication of whether or not a feature for interchangeability of body tubes is provided.BMLZ
Body Tube Interchangeability Feature:
Not provided
MRC:
An indication of whether or not a body tube analyzer is included.BMMB
Body Tube Analyzer:
Not included
MRC:
An indication of whether or not the body tube is provided with a bertrand lens.BMMC
Body Tube Bertrand Lens:
Not provided
MRC:
An indication of whether or not a body tube accessory slot is provided.BMMD
Body Tube Accessroy Slot:
Not provided
MRC:
The physical configuration of the stage.BMMF
Stage Shape:
Rectangular
MRC:
Indicates the type of stage provided.BMMH
Stage Type:
Mechanical
MRC:
An indication of whether or not mounted cross hairs are provided.BMSR
Mounted Cross Hairs:
Provided
MRC:
An indication of whether or not the item design provides for use of disc inserts.BMST
Disc Insert Usage Design:
Not provided
MRC:
Indicates the type of objective provided.BMTH
Objective Type:
Dry
MRC:
An indication of the stage calibration facility provided.BPFB
Stage Calibration Facility:
Graduated scale
MRC:
The design of the nosepiece.BPFK
Nosepiece Design:
Turret
MRC:
The number of place(s) provided on the nosepiece.BPFL
Nosepiece Place Quantity:
3
MRC:
The number of objective(s) provided.BPFM
Objective Quantity:
3
MRC:
The designation indicating the amount of apparent enlargement by a divisible objective,excluding the front element.BPFN
Divisible Objective Power Excluding Front Element:
1 and 3
MRC:
An indication of whether or not a mounted micrometer scale is provided.BPFR
Mounted Micrometer Scale:
Provided
MRC:
The number of eyepiece(s) provided.BPFW
Eyepiece Quantity:
1