رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electronic Control Amplifier
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+160.0 degrees fahrenheit
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
664687-56232
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
115.000 volts input
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
65.6 volts
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
1 meter
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, coaxial rear and receptacle, coaxial bottom
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Engine analyzer