وصف:
Pressure And Temper Relief Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" and "adqn" only if flanged one or two ends
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-20.0 degrees fahrenheit
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
165.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Unthreaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Socket w/brazing ring
MRC:
The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
First End Pipe Size Accommodated:
0.750 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Polyamide nylon
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Steel, aisi 440c
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The predetermined pressure at which the item is calibrated to open.ADSV
Opening Pressure Setting:
1155.0 pounds per square inch
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
1230.0 cubic feet per minute
MRC:
An indication of whether or not the temperature is adjustable.AEVX
Tempurature Adjustability:
Adjustable
MRC:
Indicates the type of temperature control device that actuates the item.AFKX
Tempurature Control Device Type:
Thermostatic