Name plate on case marked vaccum pressure guage, red mark on dial equals 750 psi at 65 degrees f, green mark equals 750 degrees f, yellow mark equals 750 psi at 160 degrees f
TXT
وصف:
Dial Indicating Pressure Gage
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
1.040 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.313 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.313 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.125 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Anodized
MRC:
Indicates the type of actuation provided.APCM
Actuation Type:
Single coil helical bourdon tube
MRC:
An indication of whether or not the item is adjustable.APCS
Adjustability:
Nonadjustable
MRC:
An indication of the scale range.APSK
Scale Range:
+0.000/+3000.000 pounds pressure per square inch
MRC:
The nomenclature by which the scale is identified.AQFZ
Scale Name:
Pressure
MRC:
Designates the size of the relative or proportionate dimensions of the dial.ARCH
Dial Size:
1.188
MRC:
The number of connections furnished.ASMM
Connection Quantity:
1
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Indicating
MRC:
An indication of the marking(s) on the scale.ASTW
Scale Marking:
Psi
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Single
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
750.0 pounds per square inch
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
External
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rigid stem
MRC:
The degree of conformity of a scale measurement to a standard or a true value.BGKS
Scale Accuracy:
4 percent full range
MRC:
The element,compound,or mixture of which an actuating element is fabricated,excluding any surface treatment.BGKY
Actuating Element Material:
Nickel-chromium-iron alloy
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
Minor graduation green, black figures on white, minor graduation red, major graduation yellow on white
MRC:
Indicates the connection location.BGRY
Connection Location:
Back
MRC:
The element,compound,or mixture of which the protective crystal is fabricated,excluding any surface treatment.BHMF
Protective Crystal Material:
Plastic, methyl-methacrylate
MRC:
Designates the size of the connection provided.BHMG
Connection Size:
0.438 in. Npt dia
MRC:
An indication of whether or not a connector type vent is provided.BHMK
Connector Type Vent:
Not provided