رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Taper post
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.539 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
8.563 inches
MRC:
The composition of the electrolyte used in the battery.AEXT
Battery Electrolyte:
Acid
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
W/j-3 (i-40), j-35(tg-180) engines
MRC:
An indication of whether or not a feature is included for the item to be operated in a specified depth of water without malfunction.AGEB
Fording Feature:
Not included
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The amount of electrical energy the item is rated to deliver.AQGK
Ampere Hour Capacity:
34.00
MRC:
The specified time at which the capacity of the item is rated,expressed in hours.AQGL
Time Capacity In Hours:
2.00
MRC:
The specified time at which the discharge of the item is rated,expressed in minutes.AQGM
Discharge Time In Minutes:
3.75
MRC:
The number of cells contained in the item.AQGQ
Cell Quantity:
6
MRC:
An indication of whether or not a nonspilling feature is included.AQHD
Nonspilling Feature:
Included
MRC:
The amount of electrical energy the item is rated to discharge,expressed in amperes.AQHE
Discharge Rate In Amps:
540.00
MRC:
An indication of whether or not a charge indicator is included.AQHF
Charge Indicator:
Not included
MRC:
An indication of whether or not an electrolyte level indicator is included.AQHG
Electrolyte Level Indicator:
Not included
MRC:
The condition of the item when stored and/or shipped.AQHH
Storage/shipment Condition:
Dry charged
MRC:
An indication of whether or not an integral charging facility is included.AQHJ
Integral Charging Facility:
Not included
MRC:
Indicates the type of design which describes the case.CWFH
Case Design Type:
Filling plug openings
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
12.0
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
K-1 type