رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Integral vapor purge lubricating system, discharge smoke arrestor
TXT
وصف:
Rotary Vacuum Pump Unit
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
0.500
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
22.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
22.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
15.000 inches
MRC:
The cooling medium used to maintain the required operating temperature of the item.ACZV
Cooling Medium:
Air
MRC:
Indicates the type of pumping element included on the item.AENG
Pumping Element Type:
Rotary piston
MRC:
The length of a straight line which passes through the center of the intake connection,and terminates at the inside circumference.AENN
Intake Connection Inside Diameter:
0.750 inches
MRC:
The length of a straight line passing through the center of the discharge connection,with terminated points on the inside circumference.AEPJ
Err Default:
Err default
MRC:
The speed of the drive shaft required to produce the rated capacity of an item,expressed in revolutions per minute.AEQC
Operating Speed At Rated Capacity In Rpm:
1800.0
MRC:
The volume of air passed per unit of time through an item.AEQH
Air Displacement Rate:
8.5 cubic feet per minute in free air
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor